Hotline0513-83351077

Service Hotline:0513-83351077 Tel:0513-833519400513-83841007
Fax:0513-83351087
SLP Flame arrestor
SLP flame arrestor is a safety device used to arrest the flammable gas and liquid in the pipe to fire along the pipe. It is often used in torch system, heating furnace fusel system, oil recovering system and combustible gas system of transfer and relief gas pipes to prevent those systems running safely.


1¡¢SLP-I flame arrestor
Type
DN
Size mm
Remark
D
H
SLP-1-15
15
§¶108
330
Design pressure 1.0MPa
Design temperature:£¼80oC
SLP-1-20
20
§¶108
334
SLP-1-25
25
§¶159
338
SLP-1-32
32
§¶159
372
SLP-1-40
40
§¶219
376
SLP-1-50
50
§¶219
376
SLP-1-65
65
§¶219
456
SLP-1-80
80
§¶273
458
SLP-1-100
100
§¶273
462
SLP-1-125
125
§¶325
490
SLP-1-150
150
§¶325
506
Material
Shell
Flame arresting net
Carbon steel or stainless steel
Stainless steel wires
2¡¢SLP-II flame arrestor
Model
DN
Size mm
Remark
D
H
SLP-II-25
25
310
170
Design pressure£º1.0MPa
Design temperature£º£¼200oC
SLP-II-40
40
310
170
SLP-II-50
50
310
170
SLP-II-80
80
320
230
SLP-II-100
100
360
305
SLP-II-150
150
390
355
SLP-II-200
200
460
450
SLP-II-250
250
490
500
Material
Shell
Flame arresting core
Carbon steel or stainless steel
Stainless steel wires
3¡¢SLP-III flame arrestor
Type
DN
Size mm
Remark
L
d
D
SLP-III-50
50
204
§¶159
§¶280
Design pressure£º1.0MPa
Design temperature£º£¼100oC
SLP-III-80
80
206
§¶219
§¶335
SLP-III-100
100
210
§¶273
§¶390
SLP-III-150
150
218
§¶377
§¶500
SLP-III-200
200
222
§¶426
§¶565
SLP-III-250
250
228
§¶480
§¶615
SLP-III-300
300
234
§¶530
§¶670
SLP-III-400
400
246
§¶630
§¶780
Material
Shell
Flame arresting net
Carbon steel or stainless steel
Stainless steel wires


4¡¢SLP-IV flame arrestor
Type
DN
Size mm
Remark
L
d
D
SLP-IV-200
200
§¶400
770
500
Design pressure¡Ü1.0MPa
Design temperature:£¼80oC
SLP-IV-225
225
§¶400
770
500
SLP-IV-250
250
§¶500
820
550
SLP-IV-300
300
§¶500
820
550
SLP-IV-350
350
§¶600
890
610
SLP-IV-400
400
§¶600
890
610
SLP-IV-450
450
§¶800
1015
730
SLP-IV-500
500
§¶800
1175
800
Material
Shell
Flame arresting net
Q235-A
Stainless steel wires
5¡¢SLP-VÐÍ back-fire relief ventilative cover
Type
L
H
SLP-V-40
180
125
SLP-V-50
180
155
SLP-V-80
210
160
SLP-V-100
250
160
SLP-V-150
290
175
6¡¢SLP-VI(T) oxygen pipe flame arrestor
SLP-VI (T) oxygen pipe flame arrestor and the flame arrestor after oxygen pipe valve is constructed by welding some cupper alloy, stainless steel and carbon steel. It functions fire resistance in oxygen pipe by cutting off fire source to prevent explosion accidence. During the process of oxygen transfer, it plays an important role and shows its superiority of flame resistance.
Notes:
¢Ù1¡¢3¡ªmaterial: 0Cr18Ni9Ti, 1Cr18Ni9Ti or 20;
¢Ú2 ¡ªmaterial: T1¡¢T2¡¢TU1¡¢ TU2¡¢B10

Nominal pressure 2.94MPa
Specifications£¨mm£©
Model of oxygen pipe flame arrestor
Size (mm)
Model of the flame arrestor after oxygen pipe valve
Size (mm)
DN
SLP-VI
D
L
SLP-VI(T)
D
L
15
SLP-VI-15
18
600
SLP-VI(T)-15
18
1600
20
SLP-VI-20
25
600
SLP-VI(T)-20
25
1600
25
SLP-VI-25
32
600
SLP-VI(T)-25
32
1600
32
SLP-VI-32
38
600
SLP-VI(T)-32
38
1600
40
SLP-VI-40
45
600
SLP-VI(T)-40
45
1600
50
SLP-VI-50
57
600
SLP-VI(T)-50
57
1600
65
SLP-VI-60
76
600
SLP-VI(T)-65
76
1600
80
SLP-VI-80
89
600
SLP-VI(T)-80
89
1600
100
SLP-VI-100
108
600
SLP-VI(T)-100
108
1600
125
SLP-VI-125
133
600
SLP-VI(T)-125
133
1600
150
SLP-VI-150
159
600
SLP-VI(T)-150
159
1600
200
SLP-VI-200
219
600
SLP-VI(T)-200
219
1700
250
SLP-VI-250
273
600
SLP-VI(T)-250
273
1700
300
SLP-VI-300
325
600
SLP-VI(T)-300
325
1700
350
SLP-VI-350
377
600
SLP-VI(T)-350
377
1700
400
SLP-VI-400
426
600
SLP-VI(T)-400
426